+MGO CC, Marine Gasoline Oil Control Cabinet
Solutions based on the FMU product, which are installed and prewired, so we save time on commissioning.
- Equipment certificated by all mayor classification companies: DNV, BV, ABS, LLoyd, DNV
- Upgrade of system to Flow feedback, using Kral Volumeter proven for many years in boiler systems
- Additional Fuel/Air curve inside SBS-FMU, no need to upgrade existing ACC in the BCP (Boiler Controll Panel)
- Easy to commision, so saving time needed for commissioning
- Flow feedback signal selection between pick up & 4-20mA transmiter
- HFO operation Pressure feedback forwarding as before
- MGO operation Flow feedback forwarding but manipulated over Fuel/Air table
- Advanced Boiler protection:
1) Flow too hi shutdown (En/Dis)
2) MGO temperature Hi Alarm
3) Backfire protection (for Pressure feedback)
4) Backfire protection (for Flow feedback)
5) Wrong sprayer selection blocking & indication
- System aplicatible to all Boilers with positioners
- Dimensions: 500 x 500 x 300mm